The result is power expressed on a linear watt scale. Use it to compare equipment limits, transmitter output or received-signal power only when the original dBm value refers to the same measurement point and bandwidth. Cable loss, antenna gain and amplifier gain are usually combined as dB gains or losses before converting the final dBm value.
A negative dBm value does not mean negative power. It means positive power below the 1 mW reference. Likewise, adding dBm values is generally invalid; add gains and losses in dB to a dBm level. Because this page rounds to four decimal places, independently calculate or retain more precision for levels below about −40 dBm.
When combining independent powers, first convert each dBm value to a linear unit, add the watt or milliwatt values, and convert the total back if needed. For example, two equal 0 dBm sources contain 1 mW each, so their ideal summed power is 2 mW, about 3.01 dBm rather than 0 dBm or 0 dBm squared. Whether powers can physically be combined also depends on phase, circuit topology and measurement setup.
Receiver sensitivity, conducted transmitter power and radiated power are not interchangeable labels. Antenna gain and feed-line loss affect EIRP or ERP, and regulations may specify which quantity and bandwidth to use. Preserve the measurement context along with the converted number.